NEW to ZoningSupply - Insertable (Retrofit) Dampers

HVAC Contractors, Productszoning supplyComment

We are proud to announce the continuation of our damper product line here at ZoningSupply.com with the "Insert-able" damper.

Ecojay SmartZone Slip-in insertable damper

Some applications call for dampers that can be "slipped" into round duct that is spiral or other hard pipe style duct.  This is not intended for use with flex-duct but can be used with any other type of hard duct.  Simply cut a slit in the duct, insert the damper and screw it down.

Ecojay SmartZone Insertable Damper
PRO-Grade Insert Zone Damper (Retrofit)
from $49.99

4", 5", 6", 7", 8", 9", 10" ROUND Diameter Dampers

12” & 14” Diameter insert dampers require additional hole to be drilled in duct opposite damper. (grommet included to insert shaft)

FEATURES:
Industry-leading quality & highest reliability, Belimo Motor, Full-seal gasket blade, makes mounting in any round duct easy with these super-heavy duty retro-fit slip-in dampers

NOTE: All dampers subject to a 10% restocking fee.
 

Motor:
Diameter:
Quantity:
Add To Cart

SmartZone is great for fireplace season... no more cold areas.

homeowners, Other HVACzoning supplyComment

Most people enjoy a good crackling fireplace when it's cold and snowy during the winter months even it isn't the primary source of heat for our homes these days... at least for most of us.  One problem that is common with homes that only have a single thermostat (no zoning) is that when a fire is burning, areas away from the fire get colder than the rest of the house.  Zone control can be the perfect solution...

2016 USER QUESTIONS - SmartZone Advanced

Support, homeownerszoning supplyComment
Photo by BackyardProduction/iStock / Getty Images

QUESTION: I have two 9580 thermostats one in the office, the other in the main hangar bay (two zones).  When heating both zones or only the hangar, I need the furnace to go full blower with normal scheduling through stages 1 and 2.  When servicing only the small office area, I don't want the system to advance from stage 1.  Unfortunately, the office is so small and the modulating schedule of the furnace is still too much airflow for the office (the zone bypass when servicing the office is the main hangar modulating damper that is controlled via SPC (excess dumps into hangar)).  This damper will be wide open during call for hangar heat.  The main damper control logic is managed through a 3PDT  24 Vac relay. So, I need to block out stage 2 from only 1 zone (office).  The zone ramping schedule of the 9580 works well with the 100k modulating furnace control board, and would like to keep that capability. 

ANSWER: Configure the zone 1 thermostat connector STAT TYPE to G2 (conventional gas/electric) or H2 (heat pump) to allow the thermostat to control staging and use the hangar thermostat on zone 1. Wire only the stage 1 circuits (Y1 and W1) on the office thermostat to the zone 2 thermostat connector (Also connect R, C and G wires). Set dipswitch 4 to the LOCKOUT position. This will configure the zone controller to allow 2nd stage only when the hangar thermostat calls for 2nd stage regardless of whether the office thermostat is calling. When the office thermostat is calling and the hangar thermostat is not, SmartZone will not allow 2nd stage to operate.


I called last week to inquire about using this zone controller in a hangar that had a small office area and a large bay. I advised the call taker that I had Honeywell 9580. I also asked about the capability of the zone controller to handle the smaller office area’s lower CFM requirement and whether or not I could defeat the step-up from W1/Y1 to W2/Y2. I was told that the controller can be set up to defeat the stage step-ups.

After reading the manual, I found that there are no multi-stage inputs on the controller board from thermostats. So, basically, the capabilities of the Honeywell 9580 are wasted. Also, the stage defeat is for the whole system, not zone-specific as I need. It would be pointless to defeat stage increases while heating/cooling a large hangar space

ANSWER: The SmartZone controller typically controls staging based on the total system conditions which is the most efficient way to operate a multi-zoned multi-staged hvac system. However, the zone1 thermostat connector on SmartZone can be configured to allow the thermostat to control staging (refer to the top of page 10 of the installation manual). When the zone1 thermostat is configured for staging the ability to lockout 2nd stage with only 1 zone calling is disabled. With the thermostat controlling staging your ability to limit staging will be determined by the features of your Honeywell 9580 instead of the SmartZone control.


I have a honeywell mastertrol2 mm2, i wanted to update my thermostats but my zone controller has separate b and o wires going to thermostats . Will updating my zone controller to a smart zone 2 help this problem?

ANSWER: Updating your zone controller to a SmartZone 2 zone controller will allow you to use any 24VAC thermostat. SmartZone controls are designed to be universally compatible with 24VAC thermostats including WI-FI models used to control your thermostat remotely through the internet on your smart phone or tablet. You should be able to connect any 24VAC thermostat to a SmartZone control without any problems.


Do you have a digital thermostat that you recommend or sell to go with SmartZone?
From ecobee.com

From ecobee.com

ANSWER: ZoningSupply does not carry thermostats, however, SmartZone controllers are compatible with any 24VAC powered 5 or 6 wire thermostat. Popular brands our customers install with SmartZone include Honeywell, ICM, Braeburn, Nest, Ecobee, Aprilaire, Lux, Lyric,  and MANY others. We suggest you avoid using low priced 'power stealing' thermostats as they may cause intermittent issues if your utility power fluctuates. Power stealing thermostats are typically low priced and can be identified by the lack of a C (common) terminal on the thermostat wall mounting plate.
If you are looking for a WiFi thermostat check out this other article:

http://zoningsupply.com/blog/best-wifi-thermostat-for-zoning

SmartZone-2L
from $99.99
TEMP SENSOR:
Quantity:
Add To Cart

Honest discussion on homeenergypros about zoning advantages.

Other HVACzoning supplyComment

Are Zoned Heating/Cooling Systems a Good or Bad Idea?

Excerpt from homeenergypros discussion about HVAC Zone controls.

QUESTION by Jon LaMonte

 

For starters, I live in Atlanta, Ga and I am not an HVAC pro so this is a serious question that I would like answered for one of my clients.  I understand the premise of a zoned system and on the surface, it sounds like a good idea. Then I considered the fact that I have always told my customers that it is a bad idea to close off vents in rooms they are not in because of duct leakage.  Also, the second law of thermodynamics simply states the hot goes to cold, so now the unheated areas are doing their best to rob warm air from the heated areas.  Finally, if your zoning a single system, aren't you creating on oversizing issue because the unit (that was probably oversized in the first place) is now servicing a smaller area than what it was designed for?

 

Reply1 by Chris Heenan

Zoning has benefits beyond temp control. Most often the home does not require the full 2 stage heat or cooling as the system only needs to satisfy a portion of the home. So, then if 1/2 the heated air goes through a properly sized and balance bypass, the return air (from home) will mix with warm supply (from bypass) before going thru the system again. You may not need to go beyond 1stage heat (or cool) except in extremes. This is most beneficial in raising supply temps from heat pumps when in winter mode. Most supply vents feel 'cool' to homeowner. Not so when zoned and not call on all zones.

Flip it to cool, and the bypass send dehumidified cooler air across the coil. Decreasing high side pressures and amp draw of compressor. Then the air gets more heat extracted and further dehumidified. Pulling out additional condensate and running less. Remember systems have to be careful not to oversize as dehumidification is crucial to comfort. Dry and cool temps out supply vent. Not too shabby.

 

Reply2 by dale conner

Zone sytems are rarely installed properly but can be efficient if properly designed. The goal is to be able to set back the temperature a few degrees in a zone that isnt being utilized while keeping another zone comfortable that is being utilized.  A single unit with a zone system will have a by-pass duct sytem to dump the air thats been cut off from one zone back into the duct system to be used in the zone that is being used.

 

*Reply3 by James Jackson on

Have you ever been driving down the interstate hwy and come up on an exit ramp that has traffic backed up? As the traffic backs up and eventually fills the exit with cars you end up with a slight back up on the entire highway. this is the closest scenario i have been able to come up to help people understand why closing doors and vents is a bad idea. if you have a run off of a main trunk and you close the outlet or register you will cause the air to back up into the trunk causing turbulence in the trunk line resulting in a decrease in air flow in other areas on the system. this can also cause multiple other problems like pulsing and excessive noise from the increase in pressure.

another thing to remember when you shut doors in a home with no return air you cause a difference in pressure in the home. The room you have closed is now significantly positively pressurized and the house is now under a negative pressure. This why some homes have the doors undercut by 3-4 inches trying to allow the air to get back to the return.

Ok as far as the zone system goes... There is so much more thought involved in properly setting up a quality zone system that i see very few done correctly. If you want to do one correctly you first need to make sure you are using a multi-stage HVAC unit so the unit can run on low speed if it is only conditioning one zone. A bypass or crossover duct with a barometric damper is needed if you are conditioning a small zone and the air handler is still supplying too much air, but if you are going the zone route don’t use contractor grade units and piece it together with a simple zone controller. Get a high efficiency v speed unit that is designed for this application.

But what happens when you change the temps in a zone in the house 4-5 degrees?? Energy moves from hot to cold so you end up indirectly heating or cooling the entire space regardless. This brings us to another scenario. The return air in the zone that is off. My experience with working on correcting issues with homes using zone systems has been the returns are never dampered so if the zone is completely shut off you have just installed a permanent blower door. if the zone is off one you are returning hotter or colder air to the system and two you are causing that zone to have a negative pressure.

Just some things to think about !!

 

Learn more at www.zoningsupply.com

---------------------------------------------

BETTER with Zoning done right!

BETTER with Zoning done right!

Single thermostat can have issues

Single thermostat can have issues

My editorial conclusion:
Zoning CAN be effective if and ONLY if it's designed and installed properly.  This means ducts, dampers, equipment size (tons).  It also means the right zone panel setup with energy saving features like SmartZone.  Finally, to make zoning work best and comfort control and energy savings, the home owner must properly control the thermostats.  Zoning isn't a "set-it-and-forget-it" system, it must be managed to be effective.  More articles about zoning

See full discussion: http://homeenergypros.lbl.gov/group/hvac/forum/topic/show?id=6069565%3ATopic%3A7207

Best damper motor (actuator) on the market... we tested them all.

Productszoning supplyComment

Well, maybe not technically ALL of them but dozens and even more than in this photo.

We narrowed down by specs that would work for us first.  Between 30 and 60 second travel time, 90 deg rotation, at least 1.5nM torque, lower than 3.5VA power consumption, 24Vac operation, clutch free movement, minimum open/close, range of 3/8" to 1/2" shaft and more.  Once we narrowed down to here we still had about 6 or 8 motors and we tested the top 5 for full 10 year accelerated life and field testing.  Some we even used in production for a while.  We are now confident when we proclaim that the Belimo motor that is made for ecojay and we sell with SmartZone wins in all categories... reliability, noise & installation/setup.

ecojay smartzone hvac zone damper actuator motor
PRO-Grade Power Zone Damper (Round)
from $64.99
Motor:
Diameter:
Quantity:
Add To Cart
Power Open/Close Motor
from $69.99
w/ LEDs:
Quantity:
Add To Cart